5.14. Diagnostics of the air conditioning system
|
PERFORMANCE ORDER |
|
|
Step 1 - check of light-emitting diodes and active zones of the display
Check of serviceability of functioning of the HOT switch
|
PERFORMANCE ORDER |
|
|
Check of serviceability of functioning of the COLD switch
|
PERFORMANCE ORDER |
|
|
Step 2 – check of a condition of chains of the K/V information sensors on break and short circuit
|
PERFORMANCE ORDER |
||||
|
||||
Step 3 – check of serviceability of functioning of the inlet gate and gate of switching of the modes of circulation
|
PERFORMANCE ORDER |
||||
|
||||
Step 4 – check of serviceability of functioning of actuation mechanisms
|
PERFORMANCE ORDER |
||||
|
||||
Identification of actuation mechanisms
ID card of conditions of the K/V actuation mechanisms
| Number of a code | Procedure for test of the actuation mechanism | ||||
| Drive of the regime gate | Drive of the inlet gate | Drive of the mixing gate | Heater fan drive | Compressor drive | |
|
41 |
|
The closed circulation |
Maximum refrigerating capacity |
4 — 5B |
It is included |
|
42 |
|
The closed circulation |
Maximum refrigerating capacity |
9 — 11B |
It is included |
|
43 |
|
20 percent supply of fresh air |
Maximum heating |
7 — 9B |
It is switched off |
|
44 |
|
100 percent supply of fresh air |
Maximum heating |
7 — 9B |
It is switched off |
|
45 |
|
100 percent supply of fresh air |
Maximum heating |
7 — 9B |
It is included |
|
46 |
|
100 percent supply of fresh air |
Maximum heating |
10 — 12B |
It is included |
Check of serviceability of functioning of the drive of switching of the directions of distribution of air
| Position of the handle of the choice of the directions of distribution | Direction of air supply | ||
| On front level | In foot wells | On having blown in glasses | |
|
|
100% |
||
|
|
60% |
40% |
|
|
|
|
80% |
20% |
|
|
|
60% |
40% |
|
|
|
100% |
|
|
PERFORMANCE ORDER |
|
|
Step 5 – Check of serviceability of functioning of sensors of temperature
|
PERFORMANCE ORDER |
||||
|
||||
Sensor of temperature of external air
|
PERFORMANCE ORDER |
||||||
|
||||||
The air temperature sensor in salon
Example of a conclusion of identification codes of failures of the sensor switch of the gate of switching of the modes of distribution / air circulation
ID card of codes of indications of sensors switches of provision of electric motors of the drive of gates
| Code *, ** | Position of the gate | |
| On front level | In foot wells | |
|
31 |
|
Gate of switching of the modes of circulation |
|
32 |
|
|
|
34 |
|
|
|
35 |
|
|
|
36 |
|
|
|
37 |
|
Entrance gate |
|
38 |
20 percent supply of fresh air |
|
|
39 |
100 percent supply of fresh air |
|
|
|
* A conclusion to the screen of the following indications testifies to a rassoyedineniye of the contact socket of an electrical wiring of the motor of the drive of the regime gate: 32> 32> 34> 35> 36> return to 31. |
|
|
* A conclusion to the screen of the following indications testifies to a rassoyedineniye of the contact socket of an electrical wiring of the motor of the drive of the entrance gate: 37> 38> 39> return to 37. |
|
PERFORMANCE ORDER |
||||||||||
|
||||||||||
Check of serviceability of functioning of sensors switches of provision of electric motors of the drive of gates
|
PERFORMANCE ORDER |
|
|